2
RECEIVER WIRING INSTRUCTIONS
Incorrect wiring connections WILL cause damage to the
gas valve or electronic module operating the gas appliance
and may also damage the remote receiver.
Wiring Flame Function
Connect the remote receiver by connecting the two red
wires leading from the remote receiver to the red and
brown remote wires labeled “FOR USE WITH REMOTE
OR WALL SWITCH ONLY”. See Figure 2 or alternate wiring
diagrams on page 10.
Figure 2.
REMOTE
RECEIVER
ON/OFF
SWITCH REMOTE SWITCH
PIGTAIL
RED
RED
BROWN
RED
TH TH
WALL
SWITCH
TP TP
VALVE
Figure 1
NOTE: Some appliances do not have a cover plate. In-
stead, there is a hole through which the Romex clamp is
attached to the outer wrap.
1. Remove the electrical cover plate from the lower side
of the replace. Remove the knock-out from the plate
and attach the Romex clamp (screws to the outside).
See Figure 1.
2. Feed the electrical service wires through the Romex
clamp and secure the wires to the clamp.
3. Using the wire nuts provided, connect the service wires to
the junction box. The black wires to the black service wire,
the white wires to the white service wire, and the service
ground wire to the ground stud of the junction box.
4. Reattach the cover plate to the outside of the replace.
The remote receiver is powered by 110-120VAC. It plugs
into a standard polarized duplex receptacle.
Locating Receiver and Operating Functions
This remote receiver can be positioned under the rebox
in the control compartment of the replace if ambient tem-
peratures do not exceed 1700 F. This system is designed
to control the following components:
Wire Colors
• Gas Valve - Millivolt .................................................Red
Fan/Blower - 110 VAC .............................Plug from Fan
Flame Controller - HI/LO solenoid .....................Orange
REMOTE
RECEIVER
ON/OFF
SWITCH REMOTE SWITCH
PIGTAIL
RED
RED
BROWN
RED
TH TH
WALL
SWITCH
TP TP
VALVE
Canadian Equipment Requirements
This digital apparatus does not exceed the (Class A/Class
B)* limits for radio noise emissions from digital apparatus
set out in the Radio Interference Regulations of the
Canadian Department of Communications. Le present
appareil numerique n’emet pas de bruits radioelectriques
depassant les limites applicables aux appareils numeriques
(de la class A/de la class B)* prescrites dans le Reglement
sur le brouillage radioelectrique edicte par le ministere des
Communications du Canada.
This device complies with RSS-210 of Industry and Science
Canada. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this
device must accept any interference, including interference
that may cause undesired operation of the device.
Shock hazard.
Leave electrical power off at this time.
Do not restore power until the remote control
system is completely installed.
Shock hazard.
• Turn electrical power off at the circuit before
starting work.
Damage to receiver possible from elevated temperatures.
• The remote receiver should be positioned close to front
in right or left corner where ambient temperatures do not
exceed 170º F.
CAUTIONINSTALLATION INSTRUCTIONS
Installing Electrical Service to the Junction Box
WARNING
WARNING
REMOTE RECEIVER