C. Check Firebrick

Frequency: After each ash removal

By: Homeowner

WARNING! Risk of Fire! Inspect firebrick. Crumbling, deteriorated firebrick can allow overheating of surround- ing materials.

Expansion and contraction will cause minor cracking of the firebrick. This is normal. The firebrick will require peri- odic replacement depending on use.

Replace broken firebrick.

D. Inspect Grate

Frequency: After each ash removal

By: Homeowner

Inspect grate for:

Warping or sagging 1-1/2 in. (38 mm) or more

Broken welds

Burn-through of grate bars

For safe operation, replace only with an approved grate from Hearth & Homes Technologies Inc.

E. Glass Cleaning

Frequency: As desired

By: Homeowner

CAUTION! Handle glass assembly with care. Glass is breakable.

Avoid striking, scratching or slamming glass

Avoid abrasive cleaners

DO NOT clean glass while it is hot

Clean glass with a non-abrasive commercially available cleaner or ashes:

Light deposits

-Use household glass cleaner

Heavy deposits

-Use wood ash on damp cloth or,

-Use commercial fireplace glass cleaner (consult with your dealer)