29
Heat & Glo • SL-750TRS-IPI-E, SL-550TRS-IPI-E, SL-350TRS-IPI • 2120-901 Rev. G • 11/08
Figure 7.6

Top Vent - Horizontal Termination - (continued)

Three Elbows
V1 Minimum H1 Maximum H1 + H2 Maximum H1 Maximum H1 + H2 Maximum V2V1 + V2 Minimum
Model: SL-350TRS-IPI Models: SL-550TRS-IPI-E, SL-750TRS-IPI-E * *
Elbow only 1-1/2 ft. 457 mm 2 ft. 610 mm 1 ft. 305 mm 2 ft. 610 mm * *
1/2 ft.** 152 mm 2 ft. 610 mm 4 ft. 1.2 m 2 ft. 610 mm 4 ft. 1.2 m * *
1-1/2 ft.** 457 mm 3 ft. 914 mm 6 ft. 1.8 m 3 ft. 914 mm 6 ft. 1.8 m * *
2-1/2 ft.** 762 mm 5 ft. 1.5 m 10 ft 3.0 m 5 ft. 1.5 m 10 ft. 3.0 m * *
3-1/2 ft. 1.1 m 7 ft. 2.1 m 14 ft. 4.3 m 7 ft. 2.1 m 14 ft. 4.3 m * *
4-1/2 ft. 1.4 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m 14 ft. 4.3 m * *
V1 + H1 + V2 + H2 Maximum = 40 ft. (12.2 m)
*No speci c restrictions on this value EXCEPT V1 + V2 + H1 + H2 CANNOT exceed 40 ft. (12.2 m)
** See warning below
Note: Use SLP Series
components only. Note: There MUST be a 25%
reduction in total H when using
ex vent except when using the
simple up and out installation
(see Figure 5.3).
Fire Risk.
• When using SLP-HRC-SS and SLP-HRC-ZC-
SS termination caps on top vented replaces,
a one foot minimum vertical vent section is
required before installing rst elbow.
H2
H1
V2
V1
WARNING **