Hearth and Home Technologies ST1175 installation instructions Installation Instructions

Models: ST1175

1 1
Download 1 pages 27.55 Kb
Page 1
Image 1
Installation

Installation

��Instructions

Models:

ST1175

Termination Cap

These chimney termination caps have been tested for use with specific Hearth & Home Technologies Inc. (HHT) fireplaces and is a fireplace part. Refer to the fireplace installation isntructions for the correct accessories to be used. Check with your local building code agency before you begin installation to ensure compliance with local codes, including the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarification of any of the instructions contained here, contact the Heatilator Technical Services Dept., Hearth & Home Technologies Inc., 1-800-927-6841 or 1-888-427-3973.

FEET

1a

1b

3

CHASE TOP

MAX. 4-3/4 in.

(121 mm)

2

Item

Description

Qty

1a

Termination Cap - Top

1

1b

Termination Cap - Base

1

2

Slip Section

1

3

Fastener Package

1

Note: The ST1175 is designed for use with the SL1100 Series pipe.

CAUTION

Sharp Edges

Wear protective gloves and safety glasses during installation.

1.Assemble the SL1100 Series chimney Sections to within 4-3/4 in. (121 mm) below the top of the chase.

2.Remove the top by taking out the four screws that secure it to the corner posts. If the top is not screwed on, proceed to Step 3.

3.Center the partially disassembled base of the termination cap over the chimney (inside the chase). Drop the double walled slip section through the flanged opening in the base of the termina- tion cap so it telescopes both the inner and the outer chimney sections.

4.Adjust the termination cap so the slip section does not bind the chimney section. Rotate the cap so it is square with the chase and mark the position using the holes provided in the feet as a guide.

5.Drill through the chase top using a 1/8 in. (3 mm) diameter drill bit at the marked locations. Securely attach the cap to the chase using the screws provided in the fastener package.

6.Assemble the top of the termination cap and replace and tighten all the screws.

7.Caulk all screws or nails on the chase top. Periodic re-caulking may be needed to prevent leaks from developing.

Note: An arrow () found in the text signifies change in content.

Models: WARNING

Fire Risk

Intended for use with a metal chase top.

Use of combustible materials will cause a fire hazard.

Item WARNING

Fire Risk

You must use the slip section provided with this chimney top.

Single wall or other variations from the slip section MUST NOT be used.

Substitute parts may increase temperatures to adjacent combustible materials.

Hearth & Home Technologies Inc. • ST1175 Termination Cap • 34502 Rev E • 01/05