Image 18

MAINTENANCE

Installing Glass

1)Install both center and side glass onto extrusions as per diagram.

2)Place glass assembly into door frame.

3)Install retainers by placing 1 drop of glue where previously glued and put in place.

4)Install side retainers.

5)Install door catch plate.

6)Install the 24 nuts loosely, do not tighten yet.

7)Tighten side panels nuts using the following procedure:

put glue on the screws. Replace the door gasket, the two ends butt tight together on the bottom edge of the door.

8)Replace door on the stove and check the seal.

To Remove U38 Fan:

1)Unplug or disconnect power source to stove.

2)Remove all logs and the rear log support, then remove the 10 screws holding the access panel in place, see Diagram 1. (Fan is also accessible by opening the right side door. See Diagram 2).

3)Unclip the black and white wires from the fan motor.

a.tighten top & bottom outside corner nuts (2)

b.tighten inside nuts (3)

c.tighten top & bottom inside corners

(2)

8)Tighten the 10 nuts on center glass retainer.

9)Repeat step 7 for other side panel.

10)Replace new gasket by gluing it in place.

11)Install door onto stove and check the seal.

PANEL DOOR

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the nuts holding the glass retainers in place.

4)Remove the glass retainers (sides, top and bottom) and the door catch plate.

5)Replace the glass.The glass must have gasketing around it.

6)Reverse the previous steps, replace the retainers and fasten with the nuts but do not overtighten, as this can break the glass. Note: the door catch plate fits on top of the left side retainer.

7)Put gasket glue on the retainers, but do not

FAN MAINTENANCE

If your fan requires maintenance or replace- ment, access to the fan is through the access panel on the rear wall of the firebox.

Note: The unit MUST NOT be operated without the fan access panel se- curely in place and correctly sealed.

IMPORTANT: These fans collect a lot of dust from within your home. Ensure you maintain these fan mo- tors on a regular basis by vacuum- ing out the fan squirrel cages, around the motor, and around the grills on the back of the stove.

IMPORTANT

Disconnect power supply

before servicing

WARNING: Electrical Grounding In- structions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

Diagram 1

Diagram 2

4)Lift fan off of the 2 pins, tip back and pull through firebox opening. Disconnect the green ground wire from the left side of the fan as soon as you can reach it.

Replacing U38 Fan:

Reverse the above steps (1 - 4). If necessary install a new gasket before replacing the fan access panel. Make sure the fan wires and the ground wire are reattached.

18

Regency U38 ULTIMATE Freestanding Gas Stove

Page 18
Image 18
Regency U38-LP, U38-NG installation manual FAN Maintenance, Installing Glass, Panel Door

U38-NG, U38-LP specifications

The Regency U38-LP and U38-NG are innovative gas fireplaces designed to deliver both warmth and elegance to any living space. These units exemplify modern craftsmanship while ensuring high efficiency, making them popular choices among homeowners looking to enhance their indoor ambiance.

One of the key features of the Regency U38 series is its versatile design. Both models can be easily installed in a variety of settings, including new constructions and retrofits. Their clean, contemporary lines and large viewing area provide a stunning focal point for any room, allowing for maximum enjoyment of the flames. The U38-LP operates on liquid propane, while the U38-NG uses natural gas, catering to different fuel preferences and availability.

Efficiency is a hallmark of the Regency U38 series. With an impressive thermal efficiency rating, both models ensure minimal heat loss while maximizing warmth output. This efficiency not only translates into cost savings on energy bills but also contributes to a more environmentally friendly home. The switchable electronic ignition system enhances their user-friendliness, providing instant warmth with the push of a button.

The construction of the U38 fireplaces is another standout feature. They are built using high-quality materials, including a robust steel body and premium glass, ensuring durability and performance over time. Among the optional features available are customizable media options, such as glass crystals or decorative logs, allowing homeowners to personalize their fireplace to suit their tastes.

Advanced technology sets the Regency U38 series apart from traditional fireplaces. The units come equipped with an integrated, thermostatic remote control that allows users to adjust the temperature effortlessly. Additionally, the advanced airflow system ensures even heat distribution throughout the room, while the fan assist option can further enhance heat circulation.

Safety features are paramount in the design of the U38 fireplaces. They include a built-in safety shutdown system that activates if any anomalies are detected, providing peace of mind for users.

In summary, the Regency U38-LP and U38-NG fireplaces offer an ideal combination of style, efficiency, and advanced technology. Their attractive design, customizable options, energy-saving performance, and comprehensive safety features make them an excellent choice for modern homes looking for effective heating solutions without compromising on aesthetics.