Figure 10. Standing Pilot Ignition Wiring Diagram

Step 9. Wiring the Fireplace

NOTE: Electrical wiring must be installed by a licensed electrician.

CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS TO PREVENT ACCIDENTAL FIREPLACE OPERATION.

For Standing Pilot Ignition Wiring

Appliance Requirements

This appliance DOES NOT require 110-120 VAC to operate.

!WARNING: DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL VALVE OR THE AP- PLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED.

Optional Accessories

Optional fan and remote control kits require that 110-120 VAC be wired to the factory installed junction box before the fireplace is permanently installed.

Wall Switch

Position the wall switch in the desired position on the wall. An assembly of 18 ft of 20 AWG is provided with the fireplace to connect the wall switch to the appliance. Instead of the sup- plied assembly, wire with a length of 25 ft or less and a gauge of 20 AWG through 14 AWG is acceptable. The wire needs a jacket with a temperature rating of 140oF (60oC) or higher. At the appliance connect the wire to the ON/OFF switch pigtails.

WARNING: DO NOT CONNECT 110-120 VAC

!TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED.

CAUTION: LABEL ALL WIRES PRIOR TO DISCON- NECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

 

VARIABLE SPEED CONTROL

 

 

 

 

NOTE: IF ANY OF THE ORIGINAL WIRE

 

 

 

AS SUPPLIED WITH THE APPLIANCE

 

BLK

BLK

MUST BE REPLACED, IT MUST BE

 

JUNCTION BOX

REPLACED WITH TYPE 105OC RATED WIRE.

 

 

 

 

BLK

BLK

BLOWER RECEPTACLE

 

 

 

BLK

 

BLK

 

 

 

 

BLK

 

 

 

WHT

WHT

 

 

BLK

 

 

TEMPERATURE

GROUND

 

 

 

 

 

SENSOR SWITCH

 

 

 

 

 

BLOWER

 

GRN

 

 

 

BLK

WHT

 

 

110-120 VAC

BLOWER

SENSOR

 

 

SWITCH

Figure 11. Fan Wiring Diagram

“FAN”

RECEPTACLE SPEED CONTROL

16

Heat & Glo • 6000TV-OAK, 6000TV-OAK-IPI384-900 Rev. N • 11/05

Page 16
Image 16
Heat & Glo LifeStyle 6000TV-OAK Wiring the Fireplace, For Standing Pilot Ignition Wiring Appliance Requirements