Heat & Glo LifeStyle 8000TVC manual Step Positioning Leveling, Securing Fireplace

Models: 8000TVC

1 31
Download 31 pages 14.42 Kb
Page 13
Image 13

Step 5

Positioning,

Leveling, and

Securing the

Fireplace.

1.Place the fireplace into position.

2.Level the fireplace from side to side and from front to back.

3.Shim the fireplace with non-combustible material, such as sheet metal, as necessary.

4.Secure the fireplace to the framing by nailing or screwing using the nailing tabs.

Step 6

The Gas Control

Systems

The diagram below shows how to properly position, level, and secure the fireplace.

WARNING:

To ensure proper clearances the front framing header must be installed on its narrow edge and to the front of the frame.

NOTE:

Non-combustible material that is supplied with unit is not shown for clarity.

Figure 7. Proper Positioning, Leveling, and

Securing of a Fireplace

WARNING

THIS UNIT IS NOT FOR USE WITH

SOLID FUEL.

Two types of gas control systems are used with these models: Standing Pilot Ignition and Direct Spark Ignition (DSI).

Standing Pilot Ignition System

This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.

WARNING

110-120 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM.

Direct Spark Ignition (DSI) System

The DSI system includes a 120V control valve, electronic module, and spark ignitor/flame sensor.

WARNING

CONTINUOUS 110-120 VAC SERVICE MUST BE WIRED TO THE FIREPLACE JUNCTION BOX IN A DSI SYSTEM.