Step 5
Positioning,
Leveling, and
Securing the
Fireplace.
1.Place the fireplace into position.
2.Level the fireplace from side to side and from front to back.
3.Shim the fireplace with
4.Secure the fireplace to the framing by nailing or screwing using the nailing tabs.
Step 6
The Gas Control
Systems
The diagram below shows how to properly position, level, and secure the fireplace.
WARNING:
To ensure proper clearances the front framing header must be installed on its narrow edge and to the front of the frame.
NOTE:
Figure 7. Proper Positioning, Leveling, and
Securing of a Fireplace
WARNING
THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
Two types of gas control systems are used with these models: Standing Pilot Ignition and Direct Spark Ignition (DSI).
Standing Pilot Ignition System
This system includes millivolt control valve, standing pilot, thermopile/thermocouple flame sensor, and piezo ignitor.
WARNING
Direct Spark Ignition (DSI) System
The DSI system includes a 120V control valve, electronic module, and spark ignitor/flame sensor.
WARNING
CONTINUOUS