Step 9
Wiring the
Fireplace
CAUTION
NOTE: Electrical wiring must be installed by a licensed electrician.
Caution: Disconnect remote controls if you are absent for extended time periods. This will prevent accidental fireplace operation.
For Standing Pilot Ignition Wiring
Appliance Requirements
•This appliance DOES NOT require
WARNING
DO NOT CONNECT
Optional Accessories
Optional fan and remote control kits require that 110- 120 VAC be wired to the factory installed junction box before the fireplace is permanently installed.
Remote Wall Switch
Position the remote wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8
m)or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/OFF switch pigtails.
WARNING: DO NOT CONNECT
VAC TO THE REMOTE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED.
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
Figure 10. Standing Pilot Ignition Wiring Diagram
14