Step 1

Locating the

Fireplace

The diagram below shows space and clearance requirements for locating a fireplace within a room.

MODELS

A

B

C

D

E

8000TVC

49

22

39 1/2

56

79

3

Installing the Fireplace

Figure 2. Fireplace Dimensions, Locations, and

Space Requirements

Clearance Requirements

The top, back, and sides of the fireplace are defined by stand-offs.

Minimum Clearances from the Fireplace to

Combustible Materials

Glass

 

Back of

Sides of

Top of

 

Front

Floor

Fireplace

Fireplace

Fireplace

Ceiling

 

 

 

 

 

 

36 inches

0

1/2 inch

1/2 inch

31/2 inches (89mm)

31 inches

(914 mm)

 

(13 mm)

(13 mm)

 

(787 mm)

 

 

 

 

 

 

The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25mm).

The minimum clearance from the top face of the fireplace to combustible finishing materials such as drywall, is one inch (25mm).

The back of the fireplace may be recessed 21 1/2 inches (546mm) into combustible construction.

Minimum Clearances from the B-Type Vent Pipe to Combustible Materials is 1 inch (25mm) all around the pipe.