C. Maintenance and Service Tasks:
Inspect |
| Maintenance Tasks | |
| 1 | Inspect for scratches and nicks that can lead to breakage when exposed to heat. | |
Doors, surrounds and |
|
| |
2 | Verify no obstructions to airflow through the louvers. | ||
fronts | |||
|
| ||
| 3 | Verify proper clearance to combustible household objects is maintained. | |
|
|
| |
| 1 | Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat. | |
|
|
| |
| 2 | Confirm there is no damage to glass or glass frame. Replace as necessary. | |
Glass assembly and |
|
| |
3 | Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact | ||
glass | |||
and operating properly. Replace as necessary. | |||
| 4 | Clean glass using a nonabrasive cleaner such as Brasso®. Replace glass assembly if severely coated with | |
|
| silicate deposits that cannot be removed. | |
| 1 | Vacuum and wipe out dust, cobwebs and debris. Use caution when cleaning these areas. Screw tips that have | |
| penetrated the sheet metal are sharp and should be avoided. | ||
Valve compartment | 2 | Remove any foreign objects. | |
| |||
|
|
| |
| 3 | Verify unobstructed air circulation. | |
|
|
| |
Logs | 1 | Inspect for broken, damaged or missing logs. Replace as necessary. | |
|
| ||
2 | Verify correct log placement and no flame impingement causing sooting. Correct as necessary. | ||
| |||
|
|
| |
| 1 | Verify burner is properly secured and aligned with pilot or igniter. | |
|
|
| |
| 2 | Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary. | |
|
|
| |
| 3 | Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay. | |
|
|
| |
| 4 | Inspect for lifting or other flame problems. | |
Burner ignition and |
|
| |
5 | Verify air shutter is clear of dust and debris. | ||
operation | |||
|
| ||
| 6 | Inspect orifice for soot, dirt or corrosion. | |
|
|
| |
| 7 | Verify manifold and inlet pressures. Adjust regulator as required. | |
|
|
| |
| 8 | Inspect pilot flame strength. Clean or replace orifice as necessary. | |
|
|
| |
| 9 | Verify millivolt output. Replace as necessary. | |
|
|
| |
| 1 | Verify operation of remote. | |
|
|
| |
Remote controls | 2 | Replace battery in remote transmitters and batteries powering receivers. | |
|
|
| |
| 3 | If fireplace will not be used for a long period of time, verify batteries have been removed. | |
|
|
|
Heat & Glo Lifestyle Collection • | 23 |