Heat & Glo LifeStyle FB-IN-S B. Junction Box Installation, C. Installation for Fan Optional

Models: FB-GRAND-S FB-IN-S

1 42
Download 42 pages 17.7 Kb
Page 17
Image 17
B. Junction Box Installation

B. Junction Box Installation

 

INSERT STRAIN RELIEF

 

AROUND CORD IN THIS END

FEED PLUG

FROM OUTSIDE OF UNIT

 

THROUGH HOLE

SIDEWALL

 

JUNCTION

 

BOX

 

SCREW

 

PROVIDED

 

Figure 9.2 Junction box installation

 

Optional Accessories

Connecting the electrical junction box is required if using a blower or remote.

Plug the cord into a convenient outlet.

An electrician may install an outlet box inside the fireplace. Place the outlet in the lower, back corner of the fireplace.

Must use cord supplied.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

Optional Accessories WARNING

Shock hazard.

Replace damaged wire with type 105º C rated wire.

Wire must have high temperature insulation.

C. Installation for Fan (Optional)

On units already installed removal of decorative front, surround and gas insert is required.

Detach flexible liner from back of unit if insert is installed.

Remove the four screws on the cover plate (see Figure 9.3).

 

FAN

COVER

 

 

PLATE

POWER

GROUND

 

WIRE

 

CORD

 

 

Figure 9.3

 

 

Bend up the tabs on the base pan (see Figure 9.4).

Place the blower in between the bend up tabs.

Install and wire the blower per instruction shipped with the fan.

The ground wire of the fan can clip on the side of the base pan.

Reinstall the cover plate back on the unit. Make sure the fan does not make contact with the back wall to prevent noise from vibration.

Heat & Glo • FB-IN-S, FB-GRAND-S783-910 Rev. D • 3/08

17