Heat & Glo LifeStyle FB-IN-S F. Glass Assembly, G. Air Shutter Setting, Removing Glass Assembly

Models: FB-GRAND-S FB-IN-S

1 42
Download 42 pages 17.7 Kb
Page 25
Image 25
F. Glass Assembly

F. Glass Assembly

Removing Glass Assembly WARNING

Handle glass doors with care.

Inspect the gasket to ensure it is undamaged.

Inspect the glass for cracks, chips or scratches.

Do NOT strike, slam or scratch glass.

Do NOT operate appliance with glass door removed, cracked, broken or scratched.

Replace glass door assembly as a complete appliance.

Removing Glass Assembly

There are two glass latches on the bottom of glass assembly.

To release glass assembly, pull latch forward and allow to retract away from glass assembly.

Remove glass assembly after both latches have been released (see Figure 11.16).

Replacing Glass Assembly

Replace the glass door on the appliance. Fasten the latches on the glass frame.

FIREBOX

SURROUND

LOCATING TABS

Figure 11.16 Glass Assembly

G. Air Shutter Setting

Optimal flame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician.

 

NG

LP

FB-GRAND-S

Full open

Full open

FB-IN-S

1/2 in.

Full open

Heat & Glo • FB-IN-S, FB-GRAND-S783-910 Rev. D • 3/08

25

Page 25
Image 25
Heat & Glo LifeStyle FB-IN-S F. Glass Assembly, G. Air Shutter Setting, Removing Glass Assembly, Replacing Glass Assembly