1 Listing and Code Approvals
A. Appliance Certification | B. BTU Specifications |
MODELS:
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Decorative Gas Log Set
STANDARD: IAS US requirements for Outdoor Gas Fireplaces, Draft
CGA 1.6 M96
The Patio Campfire has been tested in accordance with
IAS US requirements for Outdoor Gas Fireplaces, Draft
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1 or
Code.
| Max Input |
|
Model | BTUH | Orifice Size |
75,000 | #27/.144 | |
60,000 | #44/.086 |
C. High Altitude Installations
U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.
When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang- ing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop- er orifice size, check with the local gas utility.
If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.
4 | Heat & Glo LifeStyle Collection • Patio Campfire • Rev B • 08/08 |