1 Listing and Code Approvals

A. Appliance Certification

B. BTU Specifications

MODELS: PCFM-HNG, PCFML-HNG

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Decorative Gas Log Set

STANDARD: IAS US requirements for Outdoor Gas Fireplaces, Draft 4-96 and ANSI Z21.58-1995/

CGA 1.6 M96

The Patio Campfire has been tested in accordance with

IAS US requirements for Outdoor Gas Fireplaces, Draft 4-96 and ANSI Z21.58-1995/CGA 1.6-M96 for Cana- da and has been listed by Underwriters Laboratory (UL) for installation and operation as described in these installation and operating instructions.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1 or CAN/CGA-B149.1, National Gas Instal- lation Code or CAN/CGA-B149.2, Propane Installation

Code.

 

Max Input

 

Model

BTUH

Orifice Size

PCFM-HNG

75,000

#27/.144

PCFML-HNG

60,000

#44/.086

C. High Altitude Installations

U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada.

When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang- ing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop- er orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.

4

Heat & Glo LifeStyle Collection • Patio Campfire • Rev B • 08/08