4.3 TROUBLESHOOTING GUIDE

4.3 TROUBLESHOOTING GUIDE

In general, possible trouble is classified in two causes.

The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit is running but cooling is ineffective

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (Heat exchanger)

Malfunction of fan

Clogged air filter

Obstruction at air outlet

Stop auto air-swing

Correct above troubles

Check clogging in refrigeration circuit.

Repair clogging in refrigeration circuit.

Check outdoor coil

(heat exchanger) & the fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air ; 44.6~50˚F

Check heat load increase.

Unexpected residue

Overloaded Circuit

Check inside gas pressure.

Adjusting of refrigerant charge

Malfunction of compressor

Replacement of compressor

20

Page 20
Image 20
Heat Controller BG-101A, BG-81A Troubleshooting Guide, Unit is running but cooling is ineffective, Ineffective Cooling