Heat Controller IR30S, IR60S operation manual Maintenance, Cleaning, Replacing Emitter

Models: IR60S IR30S

1 4
Download 4 pages 476 b
Page 4
Image 4
MAINTENANCE

Installation & Operation

Radiant Infrared Heater

Heat Controller

 

 

 

MAINTENANCE

There are only two maintenance procedures which can be done on location: cleaning the unit and replacing the emitter. Return the heater to an au- thorized service faciity for any other electrical or mechanical adjustment or repair, including replace- ment of a damaged power cord.

Should the heater be dropped or damaged, or mal- function at any time, immediately turn off the main power source and do not use heater until it has been examined by an authorized service facility.

CLEANING

To remove dust or dirt on the reflector, follow these steps:

1.Turn the power switch OFF and disconnect heater from the main power supply.

2.Remove the wire guard and carefully wipe the reflector with a soft, lint-free cloth.

CAUTION: Do not touch the emitter. Finger marks will burn into the quartz emitter during use and cause premature heater failture.

If emitter is inadvertently touched, or if it needs to be cleaned, carefully wipe it using rubbing alcohol or methylated spirits.

REPLACING EMITTER

Contact your distributor for the correct replacement emitter, providing the model number and rating from the rating label. Not using an exact replacement emiitter can cause the heater to fail.

IMPORTANT: Read through the emitter replacement procedure below before beginning the replacement.

CAUTION: Do not touch emitter with bare hands. Wearing soft cotton gloves is highly recommended.

1.Turn OFF power switch and disconnect from main power supply (circuit breaker).

2.Be sure the heater and emitter are cool: burns can result from touching hot components.

3.Remove the screws from the end of the heater fixture and remove the aluminum end cap.

4.Carefully slide the perforated front grille immedi- ately adjacent to the end cap off the end of the unit.

5.Carefully slide the protective grille to the end of the heater to expose the emitter and silicone seal- ing connectors.

6.Carefully remove the emitter and silicone wire connectors from the aluminum emitter clips, free- ing the wire/connector system.

7.Carefully remove the silicone terminal connec- tors from the ends of the emitter. Be careful not to break the emitter terminal end inside the silicone wire connector. Discard the used emitter.

8.Holding the new emitter by the ceramic ends OR wearing clean dry gloves, place the silicone termi- nal connectors onto the new emitter and re-clip it into the emitter holder.

9.Carefully slide the protective grille and perforated end cap into place, and replace screws.

Due to ongoing product improvements, specifications and dimensions are subject to change and correction without notice and without incurring obligations. Determining the application and suitability for use of any product is the responsibility of the installer. Addition- ally, the installer is responsible for verifying dimensional data on the actual product prior to beginning any installation preparations.

Incentive and rebate programs have precise requirements as to product performance and certification. All products meet applica- ble regulations in effect on date of manufacture; however, certifi- cations are not necessarily granted for the life of a product. There- fore, it is the responsibility of the applicant to determine whether a specific model qualifies for these incentive/rebate programs.