Heat Controller IR60S, IR30S Introduction, Electrical Installation, WALL-MOUNTED Installation

Models: IR60S IR30S

1 4
Download 4 pages 476 b
Page 3
Image 3

Installation & Operation

Radiant Infrared Heater

Heat Controller

 

 

 

INTRODUCTION

Heat Controller’s infrared heater produces radiant heat that warms people and objects rather than the air surrounding them. The heater can be mounted on a wall or ceiling, and adjustable brackets allow the heat to be directed where desired.

This heater is designed for outdoor commercial use only.

ELECTRICAL INSTALLATION

WARNING: To assure safe operation, installa- tion must be done by a certified electrician and must adhere to local, state and national electrical codes.

4.Secure the electrical supply cable so it does not come in contact with the heater body or obstruct the air vents. Follow local and national electrical code requirements.

Use a certified ground fault protection device for wet environment installations.

1.Supply voltage must correspond to the voltage indicated on unit’s rating plate.

2.The cord from each terminal box must be hard wired and properly grounded.

WARNING: Each power supply circuit must be provided with a means of disconnection, and the disconnecting means must be grouped.

MINIMUM CLEARANCE DISTANCES FROM...

 

 

 

ADJACENT

MODEL

FLOOR

CEILING

WALLS

IR30S

8' (2.44 m)

1' 8" (.51 m)

36" (.91 m)

IR60S

10' (3.05 m)

1' 8" (.51 m)

48" (1.22 m)

WALL-MOUNTED INSTALLATION

WARNING: Observe minimum clearances shown in chart above.

1.Securely fasten the L-shaped brackets to the mounting surface using both of the fixing holes in the short part of the bracket. NOTE: Wall bolts are not supplied: select an appropriate size to provide adequate support for the weight of the unit and taking into consideration any wind load conditions.

CAUTION: If there is any question about security of bolts and fixings, contact a professional con- tractor.

2.Mount the heater to the brackets with the terminal box at the bottom of the heater.

3.Adjust the heater to the desired directional angle, then fix in this position by tightening the fixing bolts on the brackets at the rear of the heater.

CAUTION: Do not position the heater at an angle greater than 50° or less than 30°.

CEILING-MOUNTED INSTALLATION

WARNING: Observe minimum clearances shown in chart at left.

1.Heater should be hung using non-flexible mount- ing brackets (not supplied). Select brackets that will maintain a minimum clearance of 1' 8" (.51 m) from the ceiling.

2.Bolts and fixings (not supplied) should be of an ap- propriate size to provide adequate support for the weight of the unit and any additional load resulting from wind conditions.

CAUTION: If there is any question about security of bolts and fixings, contact a professional con- tractor.

3.Secure the heater to the mounting brackets with the heater facing directly down.

4.Secure the electrical supply cable so it does not come in contact with the heater body or obstruct the air vents. Follow local NEC code require- ments.

ADJUSTING DIRECTIONAL POSITIONING

WARNING! Never attempt to move heater while it is operating. Personal injury could result.

1.Power to the heater from the main supply must be OFF to adjust the position. (Turn off circuit breaker.)

2.Allow the heater to cool before re-positioning the angle.

3.Loosen the fixing bolts on the brackets at the rear of the heater; re-position heater as desired, then re-tighten the fixing bolts.

CAUTION: Do not position the heater at an angle greater than 50° or less than 30°.