Performance Data
Model BME/BML Electric Defrost 60 Hz
|
| Capacity |
| Fan Data |
|
| Air Throw*† |
|
| ||||
| Model | 10°F TD | 6°C TD |
|
|
| Diameter | Extended | Diffused | ||||
| No. | CFM | m3h | (Std.) | (Opt.) | ||||||||
|
|
|
| ||||||||||
|
| BTUH | Watts |
|
|
| in. | mm | ft. | m | ft. | m | |
| BME101 | 10,100 | 2,960 | 1 | 2,350 | 4,000 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BME140 | 14,000 | 4,100 | 1 | 2,250 | 3,830 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Inch | BME190 | 19,000 | 5,570 | 2 | 4,700 | 7,990 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
BME260 | 26,000 | 7,620 | 2 | 4,500 | 7,650 | 18 | 457 | 65 | 20 |
| 50 | 15 | |
Per |
|
|
|
|
|
|
|
|
|
|
|
|
|
BME310 | 31,000 | 9,080 | 3 | 7,050 | 11,990 | 18 | 457 | 65 | 20 |
| 50 | 15 | |
Fins6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
BME390 | 39,000 | 11,420 | 3 | 6,750 | 11,480 | 18 | 457 | 65 | 20 |
| 50 | 15 | |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BME430 | 43,000 | 12,590 | 4 | 8,800 | 14,960 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BME520 | 52,000 | 15,230 | 4 | 8,400 | 14,280 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BME620 | 62,000 | 18,160 | 5 | 10,000 | 17,000 | 18 | 457 | 65 | 20 |
| 50 | 15 |
| BML100 | 10,000 | 2,930 | 1 | 2,325 | 3,950 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BML165 | 16,500 | 4,830 | 2 | 4,900 | 8,330 | 18 | 457 | 65 | 20 |
| 50 | 15 |
Inch |
|
|
|
|
|
|
|
|
|
|
|
|
|
BML220 | 22,000 | 6,440 | 2 | 4,650 | 7,910 | 18 | 457 | 65 | 20 |
| 50 | 15 | |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Per | BML250 | 25,000 | 7,320 | 3 | 7,350 | 12,500 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
BML330 | 33,000 | 9,670 | 3 | 6,975 | 11,860 | 18 | 457 | 65 | 20 |
| 50 | 15 | |
4 Fins |
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
BML370 | 37,000 | 10,840 | 4 | 9,100 | 15,470 | 18 | 457 | 65 | 20 |
| 50 | 15 | |
| BML440 | 44,000 | 12,890 | 4 | 8,700 | 14,790 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BML530 | 53,000 | 15,520 | 5 | 10,350 | 17,600 | 18 | 457 | 65 | 20 |
| 50 | 15 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Model BME/BML Electric Defrost 50 Hz‡
|
| Capacity |
| Fan Data |
|
| Air Throw*† |
|
| ||||
| Model | 10°F TD | 6°C TD |
|
|
| Diameter | Extended | Diffused | ||||
| No. | CFM | m3h | (Std.) | (Opt.) | ||||||||
|
|
|
| ||||||||||
|
| BTUH | Watts |
|
|
| in. | mm | ft. | m | ft. | m | |
| BME101 | 8,832 | 2,590 | 1 | 2,115 | 3,600 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BME140 | 12,236 | 3,580 | 1 | 2,025 | 3,440 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Inch | BME190 | 16,652 | 4,880 | 2 | 4,230 | 7,190 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
BME260 | 22,724 | 6,660 | 2 | 4,050 | 6,890 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 | |
Per |
|
|
|
|
|
|
|
|
|
|
|
|
|
BME310 | 27,140 | 7,950 | 3 | 6,345 | 10,790 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 | |
Fins6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
BME390 | 34,132 | 10,000 | 3 | 6,075 | 10,330 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 | |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BME430 | 37,628 | 11,020 | 4 | 7,920 | 13,460 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BME520 | 45,448 | 13,310 | 4 | 7,560 | 12,850 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BME620 | 54,188 | 15,870 | 5 | 9,000 | 15,300 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BML100 | 8,740 | 2,560 | 1 | 2,093 | 3,560 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BML165 | 14,444 | 4,230 | 2 | 4,410 | 7,500 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
Inch |
|
|
|
|
|
|
|
|
|
|
|
|
|
BML220 | 19,228 | 5,630 | 2 | 4,185 | 7,120 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 | |
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Per | BML250 | 21,896 | 6,410 | 3 | 6,615 | 11,250 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
BML330 | 28,888 | 8,460 | 3 | 6,278 | 10,670 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 | |
4 Fins |
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
BML370 | 32,384 | 9,490 | 4 | 8,190 | 13,920 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 | |
| BML440 | 38,456 | 11,260 | 4 | 7,830 | 13,310 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| BML530 | 46,368 | 13,580 | 5 | 9,315 | 15,840 | 18 | 457 | 60 | 18.5 |
| 45 | 13.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*Standard molded fan guards allow for extended air throw; optional wire guards promote air diffusion
† Air throw data based on
‡ For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will
not see a reduction in performance due to the electronic control of the motor)
Capacity Correction
Factors For Electric and
Hot Gas Defrost Units
Saturated |
|
|
|
|
| |
Suction | +20 | |||||
Temperature °F |
|
|
|
|
| |
|
|
|
|
|
| |
Saturated |
|
|
|
|
| |
Suction | ||||||
Temperature °C |
|
|
|
|
| |
|
|
|
|
|
| |
Multiply | 1.15 | 1.02 | 1.00 | 0.90 | 0.80 | |
Capacity By | ||||||
|
|
|
|
| ||
|
|
|
|
|
|