Heath Zenith 52-4076 Installation, Eave Mount Wall Mount, Black to White to Black WhiteGasket

Models: 52-4075 52-4076

1 8
Download 8 pages 63.6 Kb
Page 2
Image 2

INSTALLATION

For easy installation, select an existing light operated by a wall switch for replacement.

For best performance, mount the fixture about 8 feet (2.4 m) above the ground.

Drill the holes needed to mount the backplate to the junction box.

Wire the Light Control

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Route the Light Control's wires through the large gasket hole.

Connect the junction box wires to the Light Control wires. Twist together and secure with a wire connector.

Black to

White to Black

WhiteGasket

Eave Mount

Wall Mount

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Rotate the sensor head towards the clamp screw joint.

Control Switch

Joint Clamp

Then rotate the sensor head clockwise 180° so the controls face down.

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

Mount the Light Control

Align the Light Control cover plate and the junction box holes. Secure with the mounting screws.

If not installed on a weatherproof box or if an adaptor plate (not included) was used, caulk the wall plate and mounting surface with silicone.

Avoid water damage and electrical shock - keep lamp holders below horizontal.

Lock nuts

Keep lamps at

least 1" (25 mm)

 

 

from the sensor.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting.When screwing in the flood- lamps, do not overtighten.

598-1284-00

Page 2
Image 2
Heath Zenith 52-4076 Installation, Eave Mount Wall Mount, Black to White to Black WhiteGasket, Mount the Light Control