TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.
❒Turn the SENSITIVITY (SENS) control to the mid posi- tion and the
|
| SENS |
| ||
|
|
10 5 1 TEST | MIN | MAX |
❒Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.
❒Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area.Keep the sensor at least 1" (2.5 cm) away from the lamps.
❒Adjust the SENSITIVITY as needed . Too much sensitivity may increase false triggering.
❒Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Bottom of Sensor
Avoid aiming the control at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
8 ft. | 110° |
| |
(2.4 m) |
|
60ft.
(18.3 m)
Maximum Range | Maximum |
| Coverage Angle |
The detector is most sensitive to motion across its field of view.
❒Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).
Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . Up to 60 ft. (18.3 m) [varies with surrounding temperature].
Sensing Angle. . . . Up to 110°
Electrical Load. . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . 1, 5, 10 minutes Range . . . . . . . Adjustable
Motion
Motion
Sensor
Least Sensitive | Most Sensitive |