Mode Switching Summary

 

TEST

 

 

ON-TIME Switch at 1,

 

 

 

 

 

 

 

 

 

 

 

5, or 10 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switch off for

 

 

 

 

 

 

 

one second

MANUAL MODE

 

 

 

 

 

 

then back on*

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

DualBrite® Dimmer Control

Light comes on half bright for selected time af- ter dusk (Off, 3 hr., 6 hr., until dawn).Selecting OFF disables this feature.The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 10 minutes) then returns to dim mode.

INSTALLATION

For best performance, mount the fixture about 6 feet (1.8 m) above the ground.

WARNING: Turn power off at circuit breaker or fuse.

SENS

MINMAX

4. Set sensitivity control on back of fixture to mid-position.

Wire Path

Ground Screw

5.Attach mounting plate to junction box.

This fixture comes with a universal mounting bracket. It is pre-assembled on the fixture to fit the majority of junction box applications.

However, if the slots on the mounting plate do not line up with the junction box screw holes:

1.

Remove the fixture mounting screws from

 

the mounting plate. Note: Do not remove

 

the ground screw.

2.

Attach ground wire “pigtail” to ground

 

screw on mounting plate (See Recom-

 

mended Grounding Method for additional

 

information).

1.Remove two nuts.

2.Remove Mounting Plate.

3.Tighten screws finger tight.

3. Flip the mounting plate over.