TESTING

Turn on the circuit breaker and light switch.

Note: Sensor has a 1 1/2 minute warm up pe- riod before it will detect motion.When first turned on wait 1 1/2 minutes.

Note: Meets the ENERGY STAR® guidelines when DualBrite® function is off.

Switch the on-time to TEST position and DualBrite® switch to the OFF position.

TEST 1 5 10 MIN

OFF 3 6 DUSK TO

ON-TIME

HOUR DAWN

Avoid aiming the control at:

Pools of water or objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearbylarge,light-coloredobjectsreflect- ing daylight may trigger the shut-off feature. Do not point other lights at the sensor.

150°

6 ft.

(1.8 m)

30ft.

(9.1m)

Maximum Range

Maximum

 

Coverage Angle

The detector is less sensitive to motion di- rectly towards it and more sensitive to across motion.

MotionMotion

Sensor

Least Sensitive

Most Sensitive

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head left or right to change the coverage area.

Note: Grasp the sensor only as shown and turn the entire sensor. Any other method may damage the sensor. Do not force it past the stops.

240°

Sensor Aiming

 

 

Adjustment Angle

If you need to change the sensitivity, temporarily remove the fixture and make the adjustment.Too much sensitivity may increase false triggering.

Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).

Set the amount of time after dusk you want the lights on accent level.

595-5578-09

Page 6
Image 6
Heath Zenith 595-5578-09 manual Testing, Turn on the circuit breaker and light switch, Avoid aiming the control at