WARNING: Turn power off at the circuit breaker before wiring.
Installing Sensor
Before the Installation
A
IMPORTANT: Total lighting must be from 25 to 500 watts incandescent, or 60 to 400 watts fluorescent. Less wattage than the minimum may not allow the control to work properly. The switch selected for replacement should be in a place that can detect motion in
Add Jumper At Remote
A jumper wire between the common wire and one of the switched wires is used to supply power to the 6108 regardless of the position of the remote switch.
1.Remove remote switch from the junction box.
2.Connect the jumper wire to the common lug (usually labeled on the switch) and to either one of the two switched lugs. If you're not sure which lug is common, install the jumper on any two of the wires, and test the jumper according to the flow chart on page 5.
the desired area.
For easier
In the following section you will install a jumper wire at one
Note: The existing
*Common Switch Screw
Hot Wire
Jumper Wire
To Brown wire of 6108 (note color)
To Red wire of 6108 (note color)
*The switch may indicate the common or the color of screw may be different for the common.
Figure 2 - Connecting Jumper to Remote Switch