TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

Set the ON-TIME control to the TEST position.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

ON-TIME

10 TEST

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Set the ON-TIME control to 10 minutes.

Clamp

Screw

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

180°

8 ft.

(2.4 m)

50 ft.

(15.2 m)

Maximum Range

Maximum

 

Coverage Angle

The detector is most sensitive to motion across its field of view.

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . Up to 50 ft. (15.2 m) [varies with surrounding temperature].

Sensing Angle. . . . Up to 180°

Electrical Load. . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 10 minutes Range . . . . . . . Adjustable

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

Motion

Motion

 

Sensor

Least Sensitive

Most Sensitive

598-1321-01

Page 3