Motion Sensor Light Control

As an ENERGY STAR® Partner, Heath®/Zenith has determined that this product meets the EN- ERGY STAR® guidelines for energy efficiency. This product is ENERGY STAR® compliant when used with 120 Watt bulbs.

Model BL-1800

Features

Turns on lighting when motion is detected.

Automatically turns lighting off.

Photocell keeps the lighting off during daylight hours.

This package includes:

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

10 Min

 

x

Manual

Until Dawn*

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the bottom

ON-TIME

 

of the sensor in the TEST position.

 

 

 

 

 

 

 

 

 

 

 

 

10

TEST

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 10

ON-TIME

minute position.

 

 

 

 

 

 

 

 

 

 

 

 

10

TEST

 

 

 

 

 

 

MANUAL MODE

Lamp Holders

Cover

 

Plate

4 Mounting

 

Screws (2 sizes)

Sensor

Gasket

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON- TIME switch in the 10 position.

1 Second OFF

then...

Light Control

2 Wire

Connectors

 

... back on.

Requirements

The light control requires 120-volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at home centers and electrical supply stores.

Mode Switching Summary

 

TEST

 

 

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 minutes

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

 

 

 

 

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.

© 2007 HeathCo LLC