INSTALLATION

For best performance, mount the fixture about 1.8 meters above the ground.

WARNING: Turn power off at circuit breaker.

1.

Remove

2. Remove

X-Bar.

 

two nuts.

 

 

WIRING

BLACK

WHITE

One Motion Light

BLACKBLACK

WHITE

WHITE

Two Motion Lights

3.Tighten screws finger tight.

SENSITIVITY

MIN MAX

4.Set sensitivity on fixture back to the mid-position.

Twist the junction box wires and the fixture wires together as shown below. Secure with wire connectors. If you have a metal junction box, you may not need the green“pigtail”.If you are unsure about the grounding method, consult your local building code.

5. Attach X-Bar to

junction box

Junction

Box

Due to the size and weight of the fixture, you may find it helpful to have an assistant hold the fixture in place while connecting the wires.

CAUTION: DO NOT connect the RED wire unless you want to control other lights from the motion sensor.

Recommended Grounding Method

Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the “pigtail” with the GND screw on the X-Bar.

Black to black

White to white

595-5770-05

Page 2
Image 2
Heath Zenith HB-4190 Series manual Installation, Wiring, Tighten screws finger tight, Black to black