Wire the Light Control

Wire the Light Control

Mount the Light Control WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fixture.

Install mounting strap to junction box using screws appropriate for your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Thread all fixture wires through the large holes in the gasket as shown.

Connect the junction box wires to the light fixture wires as shown. Twist together and secure with wire connectors.

Mount the Light Control

Align the light control cover plate and cover plate gasket. Secure with the mounting bolt.

Align the three slots in the decorative shell with the lamp holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell.

Shell Slot

Push the rubber plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

Black to Black

White to White

Gasket

Rubber Plug

Black to Black Mounting

Bolt

To avoid water damage and electrical shock, keep lamp holders 30° below horizontal.

Connect any fixture ground wire(s) to the junction box ground wire.

Lock Nut Lens White to WhiteManual backgroundManual backgroundManual background

Keep lamps at least 1" (2.5 cm) from both sensors.Do not allow the lamps to block either lens.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the flood lamps, do not overtighten.