Heath Zenith MSL360FWPB Test And Adjustment, Specifications, On-Time Range, Bottom of Sensor

Models: MSL360FWPB

1 16
Download 16 pages 54.32 Kb
Page 4
Image 4
TEST AND ADJUSTMENT
Clamp
Screw
Ball Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensors have a 1 1/2 minute warm up period before they will detect motion.When first turned on, wait 1 1/2 minutes.

NOTE:Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs.

Turn the RANGE control to the mid position (halfway between MIN and MAX) and the ON-TIME control to the TEST position.

ON-TIMEON-TIMERANGERANGE

ON-TIME RANGE

10 5 1 TEST

 

MIN MAX

MIN MAX

10 5

1 TEST

 

MINUTES

 

 

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

8 ft.

180°

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range
Maximum
per Sensor
Coverage Angle

 

per Sensor

 

360°

Maximum Range

Maximum

both Sensors

Coverage Angle

 

both Sensors

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aim- ing the sensors down will reduce coverage distance. The sensors are less sensitive to motion directly towards them.

MotionMotion

Sensor

Least Sensitive

Most Sensitive

For each sensor, loosen the clamp screw in the sensor ball joint and gently rotate the sen- sor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed. RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

Bottom of Sensor WARNING: Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle . . . . . . Up to 360° (180° each sensor) Electrical Load. . . . . . Up to 300 Watt Maximum Tung- sten [Up to 150 Watt maximum

each lamp holder.]

Power Requirements . 120 VAC, 60 Hz

Operating Modes . . . . TEST, AUTO, and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 10 minutes Range . . . . . . . . . . . . Adjustable

4

598-1351-01

Page 4
Image 4
Heath Zenith MSL360FWPB Test And Adjustment, Specifications, On-Time Range, Bottom of Sensor, per Sensor, both Sensors