TEST AND ADJUSTMENT
❒Turn on the circuit breaker and light switch.
NOTE: Sensors have a 1 1/2 minute warm up period before they will detect motion.When first turned on, wait 1 1/2 minutes.
NOTE:Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs.
❒Turn the RANGE control to the mid position (halfway between MIN and MAX) and the
ON-TIME RANGE
10 5 1 TEST |
| MIN MAX | MIN MAX |
10 5 | 1 TEST |
| |
MINUTES |
|
|
Bottom of Sensor
Avoid aiming the control at:
•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
8 ft. | 180° |
| |
(2.4 m) |
|
70 ft. |
|
(21 m) |
|
Maximum Range | Maximum |
per Sensor | Coverage Angle |
| per Sensor |
| 360° |
Maximum Range | Maximum |
both Sensors | Coverage Angle |
| both Sensors |
NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aim- ing the sensors down will reduce coverage distance. The sensors are less sensitive to motion directly towards them.
MotionMotion
Sensor
Least Sensitive | Most Sensitive |
❒ For each sensor, loosen the clamp screw in the sensor ball joint and gently rotate the sen- sor.
❒ Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.5 cm) away from the lamps.
❒ Adjust the RANGE as needed. RANGE set too high may increase false triggering.
❒ Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.
❒Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).
WARNING: Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].
Sensing Angle . . . . . . Up to 360° (180° each sensor) Electrical Load. . . . . . Up to 300 Watt Maximum Tung- sten [Up to 150 Watt maximum
each lamp holder.]
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO, and MANUAL
MODE
Time Delay . . . . . . . . 1, 5, 10 minutes Range . . . . . . . . . . . . Adjustable
4 |