Heath Zenith PF-4290 Series warranty Optional Wiring, Master, Slave, Wiring to Motion Light

Models: PF-4290 Series

1 20
Download 20 pages 22.86 Kb
Page 3
Image 3
OPTIONAL WIRING

OPTIONAL WIRING

When wiring to additional standard fixture only: Strip the motion sensor's red wire and connect to the standard light's black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A.).

Note: All wiring between fixtures should be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of the system.

This fixture is provided with a sensor rated for 360 Watts. Since the fixture is only rated

100 Watts, 260 Watts of additional load may be controlled by this sensor.

When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the marking which specifies the maximum lamp watt- age for which the fixture is suitable.

Once you have selected the fixtures to be connected and determined their maximum ratings, add these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150

Watts, and 75 Watts respectively, you have a total load of 325 Watts.

BLACK

 

BLACK

 

RED

 

 

WHITEMasterSlaveWiring to Motion Light &Wiring to Control One Motion SensingStandard Fixture

(Standard)

WHITE

BLACK

RED

BLACK

WHITE

 

RED

 

 

WHITE

 

 

 

Master

Slave

Wiring to Motion Light &

Wiring to Control One Motion Sensing

Standard Fixture

Lantern (Slave) from Another (Master)

It is also possible to wire two motion sensing coach lights so that either unit will turn on both lights at the same time (dual master system). It is recommended that only people with plenty of electrical experience attempt this configuration. Please call our customer service number (1-800-858-8501 - English Speaking Only) before attempting this wiring. If the dual master wiring is not done correctly, it can destroy both motion sensing fixtures and void your warranty.

598-1234-02

Page 3
Image 3
Heath Zenith PF-4290 Series Optional Wiring, Master, Slave, Wiring to Motion Light, Wiring to Control One Motion Sensing