❒Turn the RANGE control to the mid position and the
ON-TIME RANGE
10 5 1 TEST | 1 TEST | MIN MAX | MIN MAX |
10 5 |
| ||
MINUTES |
|
Bottom of Sensor
Avoid aiming the control at:•Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.
•Areas where pets or traffic may trigger the control.
•Nearby large,
8 ft. | 180° |
(2.4m) |
|
70 ft. |
|
(21m) |
|
Maximum Range | Maximum |
| Coverage Angle |
The sensor is less sensitive to motion directly to- wards it, most sensitive to motion across its fi eld of view.
MotionMotion
❒ Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.
❒ Walk through the cover- age area noting where you are when the lights turn on (also, the LED will fl ash several times when motion is detected).Move the sensor head up, down, or sideways to change the coverage area. Keep the sensor at least 1" (2.5 cm) away from the lamps.
❒ Adjust the RANGE as needed. RANGE set too high may increase false triggering.
❒Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.
❒Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).
Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].
Sensing Angle . . . . . . . . Up to 180°
Electrical Load. . . . . . . . Upto500Watt(4.2A)Maximum Incandescent [Up to 250 Watt maximum each lamp holder.]
Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL MODE
Time Delay . . . . . . . . . . 1 , 5, 10 minutes Range . . . . . . . . . . . . . . Adjustable
| Sensor |
Least Sensitive | Most Sensitive |
HeathCo LLC reserves the right to discontinue prod- ucts and to change specifi cations at any time without incurring any obligation to incorporate new features in products previously sold.