Heath Zenith SH-5407 Installation, Test And Adjustment, Wire The Light Control, White to White

Models: SH-5407

1 8
Download 8 pages 3.7 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of elec- trical shock.

For eave mount only:

Swing the sensor head towards the clamp

screw.

Controls

Clamp Screw

Rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls WIRE THE LIGHT CONTROL

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

These instructions show the sensor wired to fl ood- lamps.The white sensor wire is neutral.The black sensor wire is hot. The red wire is the switched "hot" wire. The lighting load (500 W, 4.2A max) is placed across the white and red wires.

WIRE THE LIGHT CONTROL

WARNING:Turn power off at circuit breaker or fuse.WARNING:Turn power off at circuit breaker or fuse.

Remove the existing light fi xture, if present.

After screwing the sensor into the wall plate, connect the junction box wires to the light control wires by twisting together and securing with wire connectors.

 

 

Red Sensor Wire to

White to White

 

Black Lamp Wire

 

 

 

Junction

Box

Lamp Holders

Black to Black

Optional: Connect additional load across the white and red wires. Total lighting load including lampheads on fi xture must not exceed 500W (4.2A).

MOUNT THE LIGHT

Followtheinstructionsthatcamewithyourlightfix- ture for mounting and adjusting the light fixture.

Keep regular PAR-38 lamps at least 1" (25 mm) from the sensor. Halogen lamps should be kept at least 2" (51 mm) from the sensor.

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute calibration period before it will detect motion. When fi rst turned on, wait 1 1/2 minutes.

-2-

598-1155-01

Page 2
Image 2
Heath Zenith SH-5407 manual Installation, Test And Adjustment, Wire The Light Control, Red Sensor Wire to, White to White