© 2008 HeathCo LLC 598-1158-04

Requirements

• Thelightcontrolrequires120-voltsAC.
• IfyouwanttouseManualMode,thecontrolmustbe
wiredthroughaswitch.
• Some codes require installation by a
qualified electrician.
• Thisproductis intendedforuse withthe enclosed
gasketandwithajunctionboxmarkedforuseinwet
locations.
LightControl
Sensor
Cover
Plate
Lamp Holders

Features

• Turnsonlightingwhenmotionisdetected.
• Automaticallyturnslightingoff.
• BulbSaver™-Extendsbulblifebyupto4xstandard
bulbs.Lightsbulbtofullbrightinunder2seconds.
• Photocellkeepsthelightingoffduringdaylighthours.
• LEDindicatesmotionwassensed(dayornight).
PlasticHanger
RubberPlug
Gasket
MountingStrap
MountingBolt
2Wire
Connectors
Thispackageincludes:
6Screws
(3sizesincluded)
OPERATION
*resetstoAutoModeatdawn.
TEST
10 5 1 TEST
ON-TIME
Putthe ON-TIME switch on the
bottomofthesensorintheTEST
position.
MANUAL MODE
ON-TIME
10 5 1TEST
...backon.
AUTO
1SecondOFF
then...
Note:Whenrstturnedonwaitabout11/2minutesfor
thecircuitrytocalibrate.
Manual mode only works at night
becausedaylightretur nsthe sensor
toAUTO.
Flipthelightswitchoffforonesecond
thenbackontotogglebetweenAUTO
andMANUALMODE.
Manual mode works only with the
ON-TIMEswitch in the 1, 5, or 10
position.
PuttheON-TIMEswitch inthe1,5,
or10minuteposition.
Mode: On-Time: Works: Day Night
Test 5Sec x x
Normal 1,5,10min. x
Manual UntilDawn* x

ModelSH-5412

Motion SensorLight Control
MeetstheENERGYSTAR®guidelines
whenusedwith120WMaxbulbs.
2Shells