Heath Zenith SH-5412 manual Test and Adjustment, Specifications, Bottom of Sensor

Models: SH-5412

1 16
Download 16 pages 3.4 Kb
Page 4
Image 4
Most Sensitive
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
Motion

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

NOTE:Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs.

Turn the RANGE control to the mid position (halfway between MIN and MAX) and the ON-TIME control to the TEST position.

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

Motion

Sensor

Least Sensitive

ON-TIMERANGE

ON-TIME RANGE

10 5 1 TEST

 

MIN MAX

MIN MAX

10 5

1 TEST

 

MINUTES

 

 

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed.

RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

8 ft.

180°

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range

Maximum

 

Coverage Angle

WARNING: Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle . . . . . . Up to 180°

Electrical Load. . . . . . Up to 240 Watt Maximum Tung- sten [Up to 120 Watt maximum each lamp holder.]

Power Requirements . 120 VAC, 60 Hz

Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 10 minutes Range . . . . . . . . . . . . Adjustable

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

4

598-1158-04

Page 4
Image 4
Heath Zenith SH-5412 manual Test and Adjustment, Specifications, Bottom of Sensor