Bulb Installation and Relamping

When relamping, turn power off and let the fixture cool.

Remove the screw that holds the glass cover shut. Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.

To insert the new bulb, push the bulb into the right socket so the bulb fits completely into the left socket.

Check that the bulb is seated properly.

Close the glass cover. Replace screw.

Mount the Light Control

Align the light control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws.

If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather sealant.

Wire the Light Control

WARNING: Turn power off at circuit breaker or fuse.

Remove the existing light fixture.

Strip about 5/8" insulation from the existing junction box wiring.

Route the light control’s wires through the large hole in the gasket.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

Mounting

White to White

 

Black to Black

 

Strap

Rubber

 

 

 

 

Plug

Mounting

Bolt

Gasket

Connect any fixture ground wire(s) and the cover plate ground screw to the junction box ground wire.

RIGHTWRONG

The halogen light must be mounted horizontally (+/- 4°).