SPECIFICATIONS

Range . . . . . . . Up to 60 ft. (18.3 m) [varies with surrounding temperature].

Sensing Angle. . . . Up to 110°

Electrical Load. . . . Up to 150Watts Maximum tung- sten

Power Requirements. 120 VAC, 60 Hz

Operating Modes. . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . 1, 5, 10 minutes Range . . . . . . . Adjustable

Replacement lamp. . T 150W (or less) halogen 120

VAC

HeathCo LLC reserves the right to discontinue prod- ucts and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

 

 

 

Light will not

1.

Light switch is turned off.

come on.

2. Halogen lamp is loose or burned

 

 

out.

 

3.

Fuse is blown or circuit breaker is

 

 

turned off.

 

4.

Daylight turn-off is in effect (Recheck

 

 

after dark).

 

5.

Incorrect circuit wiring, if this is a new

 

 

installation.

 

6.

Not aimed correctly (Re-aim the

 

 

sensor to cover desired area).

 

 

Light comes on

1. Light control may be installed in a

in daylight.

 

relatively dark location.

 

2.

Light control is in TEST (Select 1, 5

 

 

or 10 minutes for AUTO time).

 

 

Light comes on

1. Light control may be sensing small

for no apparent

 

animals or automobile traffic (re-aim

reason.

 

sensor).

 

2.

Sensitivity is set too high (Reduce

 

 

sensitivity).

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

Light stays on

1. The halogen lamp is positioned too

continuously.

 

close to the light control's sensor or

 

 

pointed at nearby objects that cause

 

 

heat to trigger the sensor (Reposition

 

 

the lamp away from the sensor or

 

 

nearby objects).

 

2.

Lightcontrol'ssensorispointedtoward

 

 

a heat source like an air vent, dryer

 

 

vent,orbrightly-paintedheat-reflective

 

 

surface (Reposition sensor).

 

3.

Light control is in Manual Mode.

 

 

(Switch to Auto.)

 

 

 

Light flashes

1.

Heat or light from the halogen lamp

on and off.

 

may be turning the light control on

 

 

and off (Reposition the lamp away

 

 

from the sensor).

 

2.

Heat being reflected from other

 

 

objects may be affecting the light

 

 

control (Re-aim sensor).

 

3.

Light control is in the TEST mode

 

 

and warming up (Flashing is normal

 

 

under these conditions).

 

 

 