TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

Turn the SENSITIVITY (SENS) control to the medium position (halfway between MIN and MAX) and the ON-TIME control to the TEST position.

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

SENS

ON - TIME

MIN MAX

10 5 1 TEST

Bottom of Sensor

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

 

heating vents and air conditioners. These heat

 

sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light

 

may trigger the shut-off feature. Do not point other

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cover- age area.Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the SENSITIVITY as needed . Too much sensitivity may increase false triggering.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Clamp

Screw

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

lights at the sensor.

8 ft.

110°

 

(2.4 m)

 

60 ft.

 

(18.3 m)

 

Maximum Range

Maximum

 

Coverage Angle

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

WARNING: Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m).

598-1159-06

Page 4
Image 4
Heath Zenith SH-5511 manual Test and Adjustment