TEST

Mode Switching Summary

TEST

 

 

 

Move ON-TIME Switch to

 

 

 

 

 

 

 

 

 

1, 5, or 20 minutes

 

 

 

 

 

AUTO

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp screw joint.

 

 

 

back on*

MANUAL MODE

 

 

 

 

 

 

 

Clamp Screw

Controls

*If you get confused while switching modes, turn the power off for one minute, then back on. After the cali- bration time the control will be in the AUTO mode.

DualBrite® Timer

Light comes on half bright for selected time after dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF disables this feature. The motion sensing features will continue to work as described in this manual. If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or 20 minutes) then returns to dim mode.

INSTALLATION

AUTOCAUTION: Keep the sensor at least 2" (51 mm) away from the bulbs.

MANUAL MODE CAUTION: To Avoid Fire Or Burn Hazards:

Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.

Keep fixture at least 2" (51 mm) from combustible materials. Do not aim at objects closer than 3' (1 m).

Use only T4 100W (max.), G8 tungsten halogen bi-pin 120 VAC bulbs.

For easy installation, select an existing light with a wall switch for replacement.

For best performance, mount the fixture about 8 ft. (2.4 m) above the ground.NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming the sensor down will reduce coverage distance.

Rotate the sensor head clockwise 180° so the controls face down.

Controls

INSTALLATION Controls  CAUTION: To Avoid Fire Or Burn Hazards:Manual background

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

Bulb Installation and Replacement

NOTE: Bulbs are included, but you will need to install them.

NOTE: When replacing bulbs, turn power off and let the fixture cool.

To remove lamp shade, loosen set screw 2 full turns with a small flat-head screwdriver.Turn shade counterclockwise and remove.

To remove bulb, pull straight out of fixture.

To replace bulb, push bulb pins into bulb socket. Check that the bulb is seated properly.

To reinstall lamp shade, place shade on fixture and align notches on shade with tabs on fixture. Turn clockwise. Tighten set screw firmly.