Controlling Non-Motion Sensing
Fixtures
❒When wiring to additional standard fixture only: Strip the motion sensor's red wire and connect to the standard light's black wire. Connect all white wires together. Total fixture ratings must not exceed 1000 Watts (8.3 A).
NOTE: All wiring between fixtures should be run in accordance with the National Electrical Code (Canadian Electrical Code in Canada) through conduit or another acceptable means.
Contact a qualified electrician if there is any question as to the suitability of the system.
❒This fixture is provided with a sensor rated for 1000 Watts. Since the fixture is only rated 300 Watts, 700 Watts of additional load may be controlled by this sensor.
❒When determining what a fixture is rated for, do not simply look at the rating on the lamp in the fixture. Look at the marking which speci- fies the maximum lamp wattage for which the fixture is suitable.
❒Once you have selected the fixtures to be con- nected and determined their maximum ratings, add these ratings up. For instance, if you have 3 fixtures rated 100 Watts, 150 Watts, and 75 Watts respectively, you have a total load of 325 Watts.
BLACK from |
| ||
Switch to |
| ||
BLACK from | RED from | ||
Security Light | Security Light | ||
|
|
| to BLACK from |
|
|
| Fixture |
|
|
| |
|
|
|
|
(Standard)
WHITE from Line | WHITE from Line |
to WHITE from | to WHITE from |
Security Light | Fixture |
Wiring to a Motion Light & Standard Fixture