Troubleshooting Wiring Connections

INSTALLATION

Mount the SL-6107 into the junction box with the two junction box screws.

Turn the circuit breaker back on.

Preset the controls: Time to min. (fully counter-clockwise), Photo Adjustment fully clockwise. Cover the lens with masking tape.

With the motion sensor in the “ON” position, turn the remote switch on and off several times. Go to step 1, 2, or 3, depending on results.

Troubleshooting Wiring Connections

* Turn power off before rewiring!

1.

2.

If light does not turn on:

If light turns on in only one position of remote switch:

Exchange*

Control's

Red Black

wires.

Exchange*

Control's

Red Brown

wires.

Test again. Go

to 2 or 3.

Test again. Go

to 1 or 3.

3.

If light turns on

with remote

switch in either

position:

Set sensor to “AUTO”. Wait for the unit to warm up (up to 1 min.). If the remote switch can turn the lights on, it's OK. Otherwise:

Exchange* Control's

Black Brown wires. Remove the tape. Go to the next page.