Heath Zenith SL-9525 manual Installation, Wall Mount, Eave Mount, White to, Gasket, Black to Black

Models: SL-9525

1 12
Download 12 pages 21.91 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

Drill out the holes if needed to mount the backplate to the junc- tion box.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

 

White to

Gasket

White

 

 

Black to White to

Black

Junction box ground wire to green ground screw on fixture.

Wall Mount

Eave Mount

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper opera- tion and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backing from the Light Shield and stick on as shown below.

For eave mount only:

Swing the sensor head towards2345678901234567the clamp screw

joint.Controls

Clamp Screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Light Shield

Opening

Controls Gasket

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

WIRE THE LIGHT CONTROL.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Route the Light Control’s wires through the large gasket hole.

MOUNT THE LIGHT CONTROL.

Align the Light Control cover plate and cover plate gasket. Secure with the screws provided.

Align the three slots in the decorative shell with the lamp holder pins. Push the shell in and then twist clockwise to lock. Repeat for other shell.

Shell Slot

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

To avoid water damage and Lock Nut electrical shock, keep lamp holders 30° below horizontal.

 

Keep lamps at least

 

1" (2.5 cm) from the

Lens

sensor. Do not allow

the lamps to block

 

 

the lens.

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.

2

595-5612-08

Page 2
Image 2
Heath Zenith SL-9525 manual Installation, Wall Mount, Eave Mount, White to, Gasket, Black to Black, Wire The Light Control