TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has about 1 1/2 minutes warm up period before it will detect motion. When first turned on, wait about 1 1/2 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

ON-TIME

RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

MIN MAX

Loosen the clamp screw in the sensor ball joint and gently ro- tate the sensor.

Walkthroughthecoveragearea noting where you are when the lights turn on (also, the LED will flash several times when mo- tion is detected). Move the sen- sor head up, down, or sideways to change the coverage area.

Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed. RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw. Do not overtighten the screw.

Clamp

Screw

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

180°

8 ft.

(2.4 m)

70 ft.

(21 m)

Maximum Range
Maximum

 

Coverage Angle

The detector is most sensitive to motion across its field of view.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5 or 10 minutes).

Warning - Risk of fire. Do not aim the lamps at a combustible surface within 3 ft. (1 m).

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with surrounding temperature].

Sensing Angle . . . . . . . . Up to 180°

Electrical Load . . . . . . . . Up to 300 Watt Maximum In- candescent [Up to 150 Watt maximum each lamp holder.]

Power Requirements . . . 120 VAC, 60 Hz

Operating Modes . . . . . . TEST, AUTO and MANUAL MODE

Time Delay . . . . . . . . . . 1 , 5, 10 minutes

DESA Specialty Products™ reserves the right to dis- continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.