Model K-450 Wiring Diagrams
120 Volts / 1000 Watts
CHANGING THE THERMOSTAT
1.Disconnect from the power source.
2.Remove rods from oven.
3.Remove element cover and pull
4.Loosen setscrew in thermostat knob and remove knob. Remove chrome mounting ring (bezel).
5.Remove nine (9) mounting screws from leg assembly and lift oven clear of leg
6.Remove electrical leads from thermostat and remove thermostat by pulling sensing tube through conduit.
7.To replace new thermostat, pass sensing tube through conduit, being sure there is adequate length to reach the holder.
8.Reconnect electrical leads to new thermostat and mount thermostat to chrome ring (bezel) loosely with red indicting line in upward position. Place knob on thermostat stem and check rotation of knob. When knob turns freely, remove and tighten chrome mounting ring (bezel)
9.Replace leg assembly being sure wiring is not crimped between oven wall and leg.
10.Replace thermostat knob.
11.Insert
THERMOSTAT CALIBRATION
1.Turn on unit. Set control dial at desired temperature.
2.Allow control to cycle at least three times and observe temperature at middle of fourth cycle.
3.If calibration is required, carefully remove dial knob. Do not turn shaft.
4.Turn calibration screw in center of dial shaft. (Turning set screw clockwise decreases temperature. Turning setscrew
5.Allow unit to cycle at least three times and observe temperature at middle of fourth cycle. Readjust calibration screw if necessary. Replace dial knob
15 AMP/
NEMA
240 Volts / 1000 Watts
Grounding Plug
NEMA
480 Volts / 1000 Watts
20 AMP/
Grounding Plug NEMA