Henny Penny 291 manual Error Code Table, Continued, Cause, Panel Board Correction

Models: 291

1 10
Download 10 pages 18.06 Kb
Page 10
Image 10
(Continued)

 

 

Model 291

1-4. ERROR CODE TABLE

 

(Continued)

 

 

DISPLAY

CAUSE

PANEL BOARD CORRECTION

“E-41”, “E-46”

Programming

Turn switch to OFF, then back to ON, if display shows any

 

Failure

of the error codes, try to reinitialize the control; if error code

 

 

persists, have the control board replaced

“E-47”

Analog converter

Turn switch to OFF, then back to ON, if “E-47” persists,

 

chip or 12 volt

have the I/O board, or the PC board replaced; if speaker

 

supply failure

tones are quiet, probably I/O board failure

“E-48”

Input system

Have PC board replaced

 

error

 

“E-70 B”

Faulty power

Have power switch checked, along with its wiring; have

 

switch, or switch

Input/Output board replaced if necessary

 

wiring;faulty

 

 

I/O board

 

“E-92”

24 VAC fuse

Have components, in 24-volt circuit (I.E., hi limit, drain switch)

 

on I/O board open

checked for shorts

904

1-10

Page 10
Image 10
Henny Penny 291 manual Error Code Table, Continued, Cause, Panel Board Correction