Model 690
|
| SECTION 4. | TROUBLESHOOTING |
| |||
|
|
|
|
| |||
|
|
|
| ||||
| Problem |
|
|
| Cause | Correction |
|
Power switch on but fryer |
| • | Open circuit | • Plug fryer in |
| ||
completely inoperative |
|
|
|
| • Check breaker or fuse at wall |
| |
|
|
|
|
|
| ||
Pressure not exhausting at |
| • | Solenoid or exhaust line clogged | • Turn off and allow fryer to cool to | |||
end of Cook Cycle |
|
|
|
| release the pressure in frypot; | have | |
|
|
|
|
|
| all lines, solenoid, and exhaust tank | |
|
|
|
|
|
| cleaned |
|
|
|
|
|
|
| ||
Operating pressure too high |
| • | Deadweight clogged | • Turn off and allow fryer to cool to | |||
|
|
|
|
|
| release the pressure in frypot; | clean |
|
|
|
|
|
| deadweight; see Preventive Mainte- | |
|
|
|
|
|
| nance Section |
|
DO NOT OPERATE UNIT IF PRESSURE GAUGE SHOWS HIGH PRESSURE CONDITIONS. SEVERE INJURIES AND BURNS WILL RESULT. IMMEDIATELY PLACE THE POWER/ PUMP SWITCH IN THE OFF POSITION, WHICH RELEASES THE PRESSURE BY ALLOW- ING THE UNIT TO COOL. DO NOT RESUME USE OF UNIT UNTIL CAUSE OF HIGH PRESSURE HAS BEEN FOUND AND CORRECTED.
| Pressure does not build | • | Not enough product in frypot | • Place full capacity product in frypot | |
|
|
|
|
| when using fresh shortening |
|
| • | Metal shipping spacer not | • Remove shipping spacer; see Unpacking | |
|
|
| removed from deadweight |
| Instructions Section |
|
| • | Pressure not programmed | • | Check programming |
|
| • | Lid gasket leaking | • Reverse or replace lid gasket | |
|
|
|
|
|
|
| Shortening not heating | • | Gas valve knob turned to the | • | Make sure gas control valve knob is |
|
|
| OFF position |
| turned to the ON position |
|
| • | Drain valve open | • | Close drain valve |
|
| • High temperature limit tripped | • | Reset high temperature limit; see | |
|
|
|
|
| Operating Components Section |
| Foaming or boiling over | • | See | • Follow | |
|
|
| and information in this |
| chart |
|
|
| manual |
|
|
|
|
|
|
| |
| Shortening not draining | • | Drain valve clogged | • Push cleaning rod through open | |
|
|
|
|
| drain valve |
|
|
|
|
|
|
| Filter motor won’t run | • | Motor overheated | • | Reset motor; see Filter Pump Motor |
|
|
|
|
|
| More detailed troubleshooting information is available in the Technical Manual, available at |
703 | www.hennypenny.com, or |