| Model 690 | ||
| In the event of a control system failure, the digital display shows an | |||||
|
| error message. These messages are coded: | ||||
|
| |||||
|
| error code is displayed, and to silence this tone, press any of the | ||||
|
| product buttons. |
|
|
| |
|
|
|
|
|
|
|
DISPLAY | CAUSE |
|
| PANEL BOARD CORRECTION | ||
|
|
|
|
|
| |
Control board overheating |
| Turn switch to OFF position, then turn | ||||
|
|
|
| switch back to ON; if display still shows | ||
|
|
|
| |||
|
|
|
| signs of overheating behind the control | ||
|
|
|
| panel; once panel cools down the controls | ||
|
|
|
| should return to normal; if | ||
|
|
|
| have control panel replaced | ||
|
|
|
|
|
| |
Shortening overheating |
| Turn switch to OFF position, then back to | ||||
|
|
|
| ON; if display shows | ||
|
|
|
| circuits and temperature probe should be | ||
|
|
|
| checked; once the unit cools down, the | ||
|
|
|
| controls should return to normal; if | ||
|
|
|
| persists, have control panel replaced | ||
|
|
|
|
|
| |
Temperature probe failure |
| Turn switch to OFF position, then back to | ||||
|
|
|
| ON; if the display shows | ||
|
|
|
| ture probe should be checked; once the | ||
|
|
|
| probe is repaired, or replaced, the controls | ||
|
|
|
| should return to normal; if | ||
|
|
|
| have control panel replaced | ||
|
|
|
|
|
|
|
Programmingfailure |
|
| Turn switch to OFF position, then back to | |||
|
|
|
| ON; if display shows | ||
|
|
|
| should be | ||
|
|
|
| Section) if the error code persists, have control | ||
|
|
|
| panel replaced | ||
|
|
|
|
| ||
Pump motor relay failure or |
| Replace relay if contacts are stuck closed; |
|
| ||
| wiring problem |
|
| check wiring on POWER/PUMP switch, or at | ||
|
|
|
| wall receptacle; L1 and N may be reversed | ||
|
|
|
|
|
| |
“E32, FAN FAIL | Air pressure switch open; clogged |
| Clean dilution box or replace blower if | |||
ERROR,CHECK | dilution box or faulty blower; open |
| necessary; have drain switch checked; reset | |||
BLOWER, CLEAN | drain switch; open high limit |
| high limit or have high limit checked | |||
DILUTIONBOX, |
|
|
|
|
|
|
CALLHENNY |
|
|
|
|
|
|
PENNYSERVICE” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 304 |
|
|