4-2. ERROR CODES

 

 

 

 

Model 690

4-2. ERROR CODES

In the event of a control system failure, the digital display shows an

 

 

error message. These messages are coded: “E-4”, “E-5”, “E-6”,

 

 

“E-32”, “E-41” and “E-71”. A constant tone is heard when an

 

 

error code is displayed, and to silence this tone, press any of the

 

 

product buttons.

 

 

 

 

 

 

 

 

 

 

DISPLAY

CAUSE

 

 

PANEL BOARD CORRECTION

 

 

 

 

 

 

“E-4”

Control board overheating

 

Turn switch to OFF position, then turn

 

 

 

 

switch back to ON; if display still shows

 

 

 

 

“E-4”, the board is getting too hot; check for

 

 

 

 

signs of overheating behind the control

 

 

 

 

panel; once panel cools down the controls

 

 

 

 

should return to normal; if “E-4” persists,

 

 

 

 

have control panel replaced

 

 

 

 

 

 

“E-5”

Shortening overheating

 

Turn switch to OFF position, then back to

 

 

 

 

ON; if display shows “E-5”, the heating

 

 

 

 

circuits and temperature probe should be

 

 

 

 

checked; once the unit cools down, the

 

 

 

 

controls should return to normal; if “E-5”

 

 

 

 

persists, have control panel replaced

 

 

 

 

 

 

“E-6”

Temperature probe failure

 

Turn switch to OFF position, then back to

 

 

 

 

ON; if the display shows “E-6”, the tempera-

 

 

 

 

ture probe should be checked; once the

 

 

 

 

probe is repaired, or replaced, the controls

 

 

 

 

should return to normal; if “E-6” persists,

 

 

 

 

have control panel replaced

 

 

 

 

 

 

 

“E-41”

Programmingfailure

 

 

Turn switch to OFF position, then back to

 

 

 

 

ON; if display shows “E-41”, the control

 

 

 

 

should be re-initialized (See Programming

 

 

 

 

Section) if the error code persists, have control

 

 

 

 

panel replaced

 

 

 

 

 

“E-71”

Pump motor relay failure or

 

Replace relay if contacts are stuck closed;

 

 

 

wiring problem

 

 

check wiring on POWER/PUMP switch, or at

 

 

 

 

wall receptacle; L1 and N may be reversed

 

 

 

 

 

 

“E32, FAN FAIL

Air pressure switch open; clogged

 

Clean dilution box or replace blower if

ERROR,CHECK

dilution box or faulty blower; open

 

necessary; have drain switch checked; reset

BLOWER, CLEAN

drain switch; open high limit

 

high limit or have high limit checked

DILUTIONBOX,

 

 

 

 

 

 

CALLHENNY

 

 

 

 

 

 

PENNYSERVICE”

 

 

 

 

 

 

 

 

 

 

 

 

 