INSTALLATION

INSTALLATION

Unit weights:

 

 

 

LCS 6:

270 lbs. (123 kg)

LCG 6

335 lbs. (152 kg)

 

 

 

 

 

continued

LCS 10

334 lbs. (152kg)

LCG 10

384 lbs. (174 kg)

 

 

 

 

LCS 1020

484 lbs. (220 kg)

LCG 1020

584 lbs. (265 kg)

 

 

 

 

 

 

 

LCS 20

686 lbs. (312 kg)

LCG 20

798 lbs. (362 kg

 

 

 

 

 

 

LCS 40

972 lbs. (442 kg)

LCG 40

888 lbs. (403 kg)

 

 

 

 

 

Fig. 3

Fig. 4

6)Installation models 6, 10, 1020

Place floor stand at the installation place and level by adjusting legs. (Fig. 3).

Minimum clearance required to neighboring equipment or walls. (page 59)

Place the unit on top of the stand. The unit’s legs must be centered on the locating pins of the stand (Fig. 4).

Unit must be level (Fig. 5).

7)Installation models 20, 40

The unit must be secured against shifting on the floor by means of floor fixtures (Fig. 6). If floor fixtures are glued to the floor (use polyurethane glue or similar), remove all grease from the floor first.

Place the unit at its final location and level by adjusting legs. (Fig. 5).

Minimum clearance required to neighboring equipment or walls. (page 59)

The area of floor under the unit where Mobile Oven Racks will roll in must be level or door will not seal. (Fig. 7).

Fig. 5

Fig. 6

Fig. 7

Electrical

8)Electrical connection

Connect the unit only according to the information given on the data plate.

Observe all regulations of your local Electrical Code.

The appliance may only be connected by a licensed electrician.

Each appliance requires an independent fused power supply line.

Connection via GFI circuit breaker is advisable.

On-site installation: provide accessible all-pole disconnection device with minimum of 18 in. (3 mm) contact gap (not required for 120v gas units.)

Connect appliance to ground.

Special voltages on request. Circuit diagram is located behind the operator panel.

Connected load for electric units:

Model

KW

 

Amps

 

 

 

 

 

208v 3Phase

240v 3 Phase

208v 1 Phase

240v 1 Phase

 

 

 

 

 

 

 

 

LCS-6

10

28

24

48

42

 

 

 

 

 

 

LCS-10

19

53

45.8

 

 

 

 

 

 

 

 

LCS-1020

31.5

87.5

75.9

 

 

 

 

 

 

 

 

LCS-20

38

105.6

91.5

 

 

 

 

 

 

 

 

LCS-40

63

175.1

151.8

 

 

 

 

 

 

 

 

60

Page 2
Image 2