INSTALLATION
continued
DO NOT attempt to use any type of gas other than that specified on the data plate. Incorrect gas supply could result in fire or explosion resulting in severe injuries and/or property damage.
To avoid possible serious personal injury, the installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI
■All Henny Penny
■Separate gas valves for the steam burner and dry heat burner are responsible for the gas supply to the individual burners. All LCG models have manual
Gas Leak Test
■After piping and fittings have been installed, check for gas leaks. A simple checking method is to turn on the gas and brush all connections with a soap solution. The appearance of bubbles indicates escaping gas. In this event, the piping connection must be redone until no bubbles occur.
Never use a lighted match or open flame to test for gas leaks. Escaping gas could result in fire or explosion resulting in severe injuries and/or property damage.
Gas pressure
■The gas pressure should be measured when all other gas appliances in the kitchen are on high flame. The minimum and maximum incoming line flow pressures should be as follows:
Natural:
Propane:
65