Henny Penny HEC-104, HEC-103, HEC-124, HEC-123 manual Special Program, Mode

Models: HEC-104 HEC-103

1 5
Download 5 pages 51.63 Kb
Page 5
Image 5
3-6. SPECIAL PROGRAM

 

 

 

 

Model HEC-103/104/123/124

3-6. SPECIAL PROGRAM

This mode includes the lock/unlock feature, control initialization, and

MODE

testing of the outputs and displays.

 

1.

Turn power switch off.

 

 

2.

Press and hold both

while turning on the power switch.

 

3.

“SP” shows in display, followed by “P=L” or P=U”.

 

4.

Press

to either lock (“P=L”) or unlock (“P=U”) the controls.

Locking the controls will not allow anyone to change the heat values of the shelves until the controls are unlocked.

5.

Press

.

 

 

6.

“In” shows in the display. Press and hold

or

to

re-initialize the controls, which sets all heat settings to “OFF”, or to factory set parameters. “In3”, “In2”, “In1” shows in the display, followed by “In-”, “SyS”, indicating the initialization is complete.

7.Press MODE .

8.“OP” shows in the display. Press and release the shelf buttons (1

to 4) to turn off and on the heat outputs for each shelf. Press and

release Manual background to turn off and on the base heat outputs. Press Manual background to turn off and on all displays and outputs.

9.Press and hold Manual background to exit Special Program Mode.

Press and hold Manual background at any time to exit the Special Program Mode, or if no buttons are pressed for 1 minute, controls auto- matically exits Special Program Mode.

3-5

503

Page 5
Image 5
Henny Penny HEC-104, HEC-103, HEC-124, HEC-123 manual Special Program, Mode