Troubleshooting
Troubleshooting Guide |
|
|
|
|
| ||
Symptom |
|
| Possible causes |
| Corrective Action | ||
|
| ||||||
|
|
|
|
| |||
Humidity level is not |
|
| Evaporator pad is clogged | Replace the evaporator pad | |||
being maintained |
|
| with mineral deposits |
| |||
|
|
| Water line is clogged with | Clean or replace conical mesh filter | |||
|
|
| mineral deposits or debris | and fluid restrictor | |||
|
|
| Humidistat | setting | is too | Increase the humidity setting on the | |
|
|
| low |
|
|
| humidistat |
|
|
| Saddle Valve is not fully | Turn the saddle valve handle in a | |||
|
|
| open |
|
|
| counterclockwise direction until it |
|
|
|
|
|
|
| stops |
|
|
| Evaporator pad is upside | Make sure the evaporator pad is | |||
|
|
| down |
|
|
| installed with the black mark up |
|
|
| Home | is | not | tightly | Seal leaks or drafts around doors |
|
|
| insulated |
|
| and windows | |
|
|
|
|
|
|
| Increase the humidistat setting (this |
|
|
|
|
|
|
| will only help, not solve the |
|
|
|
|
|
|
| problem) |
Humidifier will not |
|
| Humidistat level is too low | Increase the humidity setting on the | |||
turn on |
|
|
|
|
|
| humidistat |
|
|
| Solenoid valve is clogged | Contact dealer for service or | |||
|
|
| or broken |
|
| replacement | |
Water flows through |
|
| Solenoid valve is stuck in | Clean the solenoid valve | |||
the humidifier |
|
| the open position |
| Contact dealer for service or | ||
constantly |
|
|
|
|
|
| replacement |
|
|
| Air | pressure velocity | Contact dealer for possible solutions | ||
Rust is developing |
|
| through the evaporator |
| |||
around the |
|
| pad is too high |
|
| ||
humidifier |
|
| Leak in the water fill tube | Check the fill line for leaks | |||
|
|
| located in the base |
| Contact dealer for service or | ||
|
|
|
|
|
|
| replacement |
CareCo Service Dept.,
415 Wabash Ave., P.O. Box 200, Effingham, Illinois, 62401
or call
or email:
fiaqcustomerservice@fedders.com
10