Symptom

Troubleshooting

Troubleshooting Guide

 

 

 

 

 

Symptom

 

 

Possible causes

 

Corrective Action

 

 

 

 

 

 

 

Humidity level is not

 

 

Evaporator pad is clogged

Replace the evaporator pad

being maintained

 

 

with mineral deposits

 

 

 

 

Water line is clogged with

Clean or replace conical mesh filter

 

 

 

mineral deposits or debris

and fluid restrictor

 

 

 

Humidistat

setting

is too

Increase the humidity setting on the

 

 

 

low

 

 

 

humidistat

 

 

 

Saddle Valve is not fully

Turn the saddle valve handle in a

 

 

 

open

 

 

 

counterclockwise direction until it

 

 

 

 

 

 

 

stops

 

 

 

Evaporator pad is upside

Make sure the evaporator pad is

 

 

 

down

 

 

 

installed with the black mark up

 

 

 

Home

is

not

tightly

Seal leaks or drafts around doors

 

 

 

insulated

 

 

and windows

 

 

 

 

 

 

 

Increase the humidistat setting (this

 

 

 

 

 

 

 

will only help, not solve the

 

 

 

 

 

 

 

problem)

Humidifier will not

 

 

Humidistat level is too low

Increase the humidity setting on the

turn on

 

 

 

 

 

 

humidistat

 

 

 

Solenoid valve is clogged

Contact dealer for service or

 

 

 

or broken

 

 

replacement

Water flows through

 

 

Solenoid valve is stuck in

Clean the solenoid valve

the humidifier

 

 

the open position

 

Contact dealer for service or

constantly

 

 

 

 

 

 

replacement

 

 

 

Air

pressure velocity

Contact dealer for possible solutions

Rust is developing

 

 

through the evaporator

 

around the

 

 

pad is too high

 

 

humidifier

 

 

Leak in the water fill tube

Check the fill line for leaks

 

 

 

located in the base

 

Contact dealer for service or

 

 

 

 

 

 

 

replacement