dIXEL

Operating Manual

1592020130

 

 

 

Protection: IP20; Frontal protection: IP65

Connections: Screw terminal block 2,5 mm2 wiring.

Power supply: according to the model: 12Vac/dc, ±10%; 24Vac/dc, ±10%; 230Vac ±10%, 50/60Hz, 110Vac ±10%, 50/60Hz

Power absorption: 3VA max

Display: 2 digits, red LED, 14,2 mm high; Inputs: Up to 2 NTC or PTC probes.

Digital input: free voltage contact

Relay outputs: compressor SPST 8(3) A, 250Vac; or 20(8)A 250Vac defrost or Aux: SPDT 8(3) A, 250Vac

Data storing: on the non-volatile memory (EEPROM).

Kind of action: 1B; Pollution grade: 2;Software class: A.;

Rated impulsive voltage: 2500V; Overvoltage Category: II

Operating temperature: 0÷60 °C; Storage temperature: -30÷85 °C.

Relative humidity: 2085% (no condensing)

Measuring and regulation range: NTC probe: -40÷110°C(-40÷230°F);

Resolution: 0,1 °C or 1°C or 1 °F (selectable); Accuracy (ambient temp. 25°C): ±0,7 °C ±1 digit

14.CONNECTIONS

XR03CX –20A o 8A Compressor

NOTE: The compressor relay is 20(8)A or 16(6)A depending on the model.

NOTE: 120Vac or 24Vac/dc or 12Vac/dc connect to 6-7

XR04CX –20A o 8A Compressor

NOTE: The compressor relay is 20(8)A or 16(6)A depending on the model.

NOTA: 120Vac o 24Vac/dc o 12Vac/dc connect to 6 and 7

15.DEFAULT SETTING VALUES

 

LAB

 

 

 

DESCRIPTION

 

 

RANGE

 

DEFAULT

 

 

EL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REGULATION

 

 

 

 

 

 

 

 

 

Hy

 

Differential

 

 

 

 

0.1 ÷ 25°C/1 ÷ 45°F

 

2.0°C / 4 °F

 

 

 

 

 

 

 

 

 

 

 

 

 

LS

 

Minimum Set Point

 

 

 

-55°C÷SET/-67°F÷SET

 

-55 °C /-

 

 

 

 

 

 

55°F

 

 

 

 

 

 

 

 

 

 

 

 

US

 

Maximum Set Point

 

 

 

SET÷99°C/ SET÷210°F

 

99 °C /

 

 

 

 

 

 

99°F

 

 

 

 

 

 

 

 

 

 

 

 

ot

 

First probe calibration

 

 

-9.9÷9.9°C/-18÷18°F

0.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P2

 

Second

probe

presence

(Only

 

n – Y

 

y

 

 

XR04CX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

oE

 

Second

probe

calibration

(Only

 

-9.9÷9.9°C/-18÷18°F

0.0

 

 

 

XR04CX)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

od

 

Outputs activation delay at start up

 

0 ÷ 99 min

0

 

 

 

 

 

 

 

 

 

 

 

AC

 

Anti-short cycle delay

 

 

0 ÷ 50 min

1

 

 

 

 

 

 

 

 

 

 

 

Cy

 

Compressor ON time faulty probe

 

 

0 ÷ 99 min

15

 

 

 

 

 

 

 

 

 

 

Cn

 

Compressor OFF time faulty probe

 

0 ÷ 99 min

30

 

 

 

 

 

 

 

 

 

 

 

CH

 

Kind of Action (Only XR03CX)

 

 

cL ÷ Ht

 

cL

 

 

 

 

 

 

 

 

 

 

 

 

DISPLAY

 

 

 

 

 

 

 

 

 

CF

 

Measurement units

 

 

 

°C - °F

 

°C / °F

 

 

 

 

 

 

 

 

 

 

rE

 

Resolution (only for °C)

 

 

dE – in

 

dE

 

 

 

 

 

 

 

 

 

 

Ld

 

Default Display (Only XR04CX)

 

 

P1-P2 - SP

 

P1

 

 

 

 

 

 

 

 

 

 

 

dy

 

Display delay

 

 

 

0 ÷ 15 min

0

 

 

 

 

 

 

 

 

 

 

 

 

 

DEFROST

 

 

 

 

 

 

 

 

 

td

 

Defrost type

 

 

 

EL – in

 

EL

 

 

 

 

 

 

 

 

 

 

 

 

 

dE

 

Defrost termination temperature

 

 

-50÷50°C/-58÷122°F

 

8.0 °C / 46

 

 

 

 

 

°F

 

 

 

 

 

 

 

 

 

 

 

 

id

 

Interval between defrost cycles

 

 

0 ÷ 99 hours

6

 

 

 

 

 

 

 

 

 

 

 

Md

 

Maximum length for defrost

 

 

0 ÷ 99 min.

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dd

 

Start defrost delay

 

0 ÷ 99 min.

0

 

 

 

 

 

 

dF

 

Display during defrost

 

rt – in – SP – dF

it

 

 

 

 

 

 

dt

 

Drip time

 

0 ÷ 99 min

0

 

 

 

 

 

 

dP

 

Defrost at power-on

 

y - n

n

 

 

 

 

 

ALARMS

 

 

 

AU

 

Maximum temperature alarm

 

ALL÷99°C / ALL÷210°F

99 °C / 99

 

 

°F

 

 

 

 

 

AL

 

Minimum temperature alarm

 

-55°C÷ALU/-67°F÷ALU

-55 °C / -55

 

 

°F

 

 

 

 

 

Ad

 

Temperature alarm delay

 

0 ÷ 99 min

15

 

 

 

 

 

 

dA

 

Exclusion of temperature alarm

at

0 ÷ 99 min

90

 

startup

 

 

 

 

 

 

DIGITAL INPUT (Only XR03CX)

 

 

 

iP

 

Digital input polarity

 

cL – oP

cL

 

 

 

 

 

 

iF

 

Digital input configuration

 

EA – bA – do – dF –

EA

 

 

Au– db

 

 

 

 

 

di

 

Digital input delay

 

0 ÷ 99 min

5

 

 

 

 

 

dC

 

Compressor and fan status when open

no /Fn / cP / Fc

FC

 

door

 

 

 

 

 

 

rd

 

Regulation with door open

 

n - Y

y

 

 

 

 

 

 

OTHER

 

 

 

 

d1

 

Thermostat probe display

 

Read Only

- - -

 

 

 

 

 

 

d2

 

Evaporator probe display

 

Read Only

- - -

 

 

 

 

 

 

Pt

 

Parameter code table

 

Read Only

- - -

 

 

 

 

 

 

rL

 

Firmware release

 

Read Only

- - -

 

 

 

 

 

 

dIXEL S.p.a.

Z.I. Via dell’Industria, 27 - 32010 Pieve d’Alpago (BL) ITALY tel. +39 - 0437 - 98 33 - fax +39 - 0437 - 98 93 13 http://www.dixell.com E-mail: dixell@dixell.com

1592020130 XR03_04CX GB 16.01.07.doc

XR03CX – XR04CX

Page 28
Image 28
Hill Phoenix P074749F dimensions Connections

P074749F specifications

The Hill Phoenix P074749F is a cutting-edge refrigeration unit designed to meet the needs of modern commercial operations. With its innovative technology and robust features, this model stands out in the competitive market of refrigeration solutions, particularly for retail and food service applications.

One of the main attributes of the Hill Phoenix P074749F is its energy efficiency. It incorporates advanced refrigeration technology that significantly reduces energy consumption while maintaining optimal cooling performance. This feature not only lowers operating costs but also minimizes environmental impact, making it an eco-friendly choice for businesses committed to sustainability.

The unit is built with high-quality materials that ensure durability and longevity. Its construction can withstand the demands of a bustling commercial environment, providing a reliable solution that reduces maintenance needs and downtime. This reliability is further enhanced by the unit's user-friendly design, which allows for easy access to crucial components, making repairs and maintenance simpler for technicians.

Another noteworthy characteristic of the P074749F is its versatility. It can be configured to accommodate various refrigeration needs, with customizable options for temperature ranges and storage capacities. This adaptability makes it suitable for a wide range of applications, whether a small convenience store or a large supermarket.

In terms of technology, the Hill Phoenix P074749F integrates smart monitoring systems that provide real-time data on temperature and operational efficiency. This capability enables businesses to stay ahead of potential issues, ensuring consistent performance and product integrity. The unit's digital controls further enhance usability, allowing for precise adjustments and monitoring without the need for extensive technical knowledge.

Additionally, the Hill Phoenix P074749F features an efficient compressor system designed to optimize performance while minimizing noise levels. This focus on user comfort is vital in retail environments where customer experience is a priority.

Overall, the Hill Phoenix P074749F combines energy efficiency, durability, versatility, and advanced technology. Its features make it a preferred choice for those seeking reliable refrigeration solutions that meet the demands of modern commercial spaces.