en

9. Troubleshooting

Fault

Possible cause

Remedy

 

 

 

The power tool

The battery is discharged or fitted

The battery needs to be charged or,

doesn’t run.

incorrectly.

respectively, it must be heard to engage

 

 

with a double click.

 

Electrical fault.

Remove the battery from the power tool

 

 

 

and contact Hilti.

 

The battery is discharged/hot.

Deep discharge prevention / the elec-

 

 

 

tronics switch off. Fit the battery into the

 

 

charger.

The on / off switch

Not a fault (safety function).

Press the switch-on interlock.

can’t be pressed,

 

 

i.e. the switch is

 

 

locked.

 

 

 

 

 

Running speed

The battery is discharged or excessive

Change the battery and recharge the

suddenly drops

working pressure is applied to the power

discharged battery. Reduce the working

considerably.

tool.

pressure applied to the power tool.

The battery runs

Battery condition is not optimal.

Only NiCd batteries should be given a

down more quickly

 

conditioning charge. (Please refer to the

than usual.

 

operating instructions for the charger.)

The power tool

The deep discharge prevention system

Press the switch-on interlock and the

doesn’t restart by

switches off after the blade stalls a second

control switch again.

itself after the saw

time.

 

blade has stalled.

 

 

The battery doesn’t

The retaining lugs on the battery are dirty.

Clean the retaining lugs and check that

engage with an

 

the battery engages securely. Contact

audible double

 

Hilti Service if the problem persists.

click.

 

 

The tool or the

Electrical fault.

Switch the power tool off immediately,

battery become

 

remove the battery and contact Hilti

very warm.

 

Service.

 

The power tool has been overloaded

Use the right power tool for the job (don’t

 

 

(application limits exceeded).

use a low-powered tool for heavy work).

10. Disposal

CAUTION

Improper disposal of the equipment may have serious consequences: The burning of plastic components generates toxic fumes which may present a health hazard. Batteries may explode if damaged or exposed to very high temperatures, causing poisoning, burns, acid burns or environmental pollution. Careless disposal may permit unauthorized and improper use of the equipment. This may result in serious personal injury, injury to third parties and pollution of the environment.

CAUTION

Dispose of defective batteries without delay. Keep them out of reach of children. Do not attempt to open or dismantle batteries and do not dispose of them by incineration.

30

Page 19
Image 19
Hilti WSC 70-A36, WSC 55-A24 operating instructions Troubleshooting, Disposal, Fault Possible cause Remedy